Node filling and capping directions for optimal performance

We’re not crazy about reading directions either. But, please read these!

Follow these directions to avoid leaks, clogs, and other issues. Failure to adhere to these practices may invalidate your warranty.

Node filling and capping directions

Follow these directions to avoid leaks, clogs, and other issues. Failure to adhere to these practices may invalidate your warranty.

Black Node Filled Capped

Node Filling Directions

Recommended Needle Size

Ideal fill temperature

Capping time

18-20ga

90°F/32°C (thinner oils) – 135°F/57°C (thicker oils)

3 mins or less (depending on viscosity)

blunt

Insert a blunt tip 18 to 20g needle into the space between the center airway tube and the inner wall of the cartridge body. Caution: Do not allow oil to enter the center airway.

filling iconsArtboard 1 copy 5

90°F/32°C (thinner oils) | 135°F/57°C (thicker oils)
The ideal fill temperature will allow for filling and capping before the oil saturates the atomizer.

Stem filling iconsArtboard 1 copy 2 1

Oversaturation from hot filling, thin oils, and/or slow capping will cause flooding, clogging and leaking.

filling iconsArtboard 1 copy 3

Do not overfill your devices! Fill to a max of 1.04mL or 2.5mm from the top of the tank. Overfilling may cause seal bulging and will force fluid through the atomizer.

filling iconsArtboard 1 copy 4

Cap within 3 minutes after filling. We recommend a shorter period of time for thinner oils. Immediately after filling, cap the device with the mouthpiece until it’s fully seated.

Warning: Do not use fast or hight powered chargers that output more than 5v 1a. This may damage the battery.

Pro tip cart 4 1

PRO TIP:

FAILURE TO INSERT THE MOUTHPIECE WITHIN 3 MINUTES OF FILLING, MAY CAUSE CLOGGING OR LEAKAGE.

Node Capping Directions

Capping time

Capping method

Minimum capping force

Maximum capping force

3 mins or less
(depending on viscosity)

By hand or arbor press

28-35lbs
(13-16kg)

44lbs
(20kg)

22lbs 500 500

Make sure the mouthpiece is properly aligned and straight. Press the mouthpiece down vertically (and not at an angle) using level, even pressure, until you hear a click. This sound indicates the mouthpiece is fully seated.

Stem filling iconsArtboard 1 copy

You can seat the mouthpiece by hand, but a light-duty arbor press and jig are recommended. Do not use a hammer or mallet. Pressing at an angle can lead to damage, improper sealing, leakage, and cracking of the device.

capping iconsArtboard 1 copy 3

If too much pressure is applied during capping, you can damage the device and the battery. Check the pressure carefully.

capping iconsArtboard 1 copy 4

You cannot remove the mouthpiece once it’s fully seated without damaging the device or the mouthpiece.

capping iconsArtboard 1 copy 5

Let your devices stand for between 30 minutes to 12 hours before using. During this time, the oil is priming the atomizer. More viscous oils will require more time.

Warning: Do not use fast or hight powered chargers that output more than 5v 1a. This may damage the battery.